Mechanical hydraulic overspeed protection device
shared:

This is a high-tech product independently developed by our factory. It primarily consists of a speed detector (TCQ), a speed protector (BHQ), and a counterweight device. It serves as a purely mechanical passive overspeed protection device for large rotating equipment and can be used for overspeed protection in hydroelectric generator units.


I. Overview

The JXB-type purely mechanical hydraulic overspeed protection device is a high-tech product developed through optimized design based on the practical conditions of hydropower stations, integrating the advantages of similar products from both domestic and international markets. It primarily consists of an overspeed detector (TCQ), an overspeed protector (BHQ), and a counterweight device, serving as a purely mechanical passive overspeed protection system for large rotating equipment, applicable to the overspeed protection of hydro turbine generator units. When the rotational speed of a hydro turbine generator unit rises to the set overspeed protection threshold, but the speed signal device, power supply system, or governor system of the hydropower station fails, preventing the adjustment and shutdown of the hydro turbine generator unit, the JYSZ-type purely mechanical hydraulic overspeed protection device utilizes the oil source switching circuit of the hydraulic accumulator device. By controlling the hydraulic system through the overspeed protector (BHQ), it enables the closure of the guide vanes for axial-flow, mixed-flow, and tubular-flow hydro turbine generator units or the deflector for Pelton turbine generator units, achieving unit shutdown to prevent runaway accidents and ensuring the safe operation of the hydro turbine generator.

II. Characteristics

The JXB-type purely mechanical hydraulic overspeed protection device has a mechanical overspeed signal output for computer monitoring;

2. Compact size, easy to install and adjust;

3. Simple structure, high precision, good stability, and reliable motion performance;

4. It can be integrated with the tooth wheel speed measurement, accident pressure relief valve, segmented closing valve, and governor to form the speed protection system of the unit;

3. Technical Parameters

1. Suitable types of water turbine units: axial flow, mixed flow, cross flow, and impulse units;

2. Main spindle diameter range: 100-2500mm;

3. Rated speed range: 50-1000 rpm;

4. Operating speed range: 70-2000 rpm;

5. Rated pressure: 10 MPa;

6. Connection type: φ10 compression fitting (for copper or stainless steel tubes with an outer diameter of φ10 mm);

7. Contact type: Passive contacts, one normally open and one normally closed;

8. Contact capacity: AC 220V 5A, DC 220V 0.5A;

V. Installation

 1. Before installation, ensure that the detector mounting bracket on the main shaft is perpendicular to the turbine main shaft. If the unit's main shaft lacks a machined shoulder, methods such as marking lines on the main shaft prior to installation should be employed to guarantee the plane of the detector mounting bracket remains perpendicular to the turbine main shaft.

2. Before installation, the rust-proof protective oil on the inner surface of the detector mounting bracket (the surface that mates with the main shaft) must be thoroughly removed. Then, the counterweight device and the detector should be installed separately on the two corresponding semicircular detector mounting brackets. Afterward, the two semicircular detector mounting brackets (with the detector and counterweight device installed together) should be vertically mounted at the designated position on the water turbine main shaft. Ensure that the sides with matching serial numbers on the two semicircular detector mounting brackets are combined, and the side with serial numbers faces upward.

3. Install the overspeed protector BHQ (to be configured by the owner based on site conditions, ensuring sufficient space for manual reset) and leave the installation bolts of the overspeed protector BHQ slightly loose for future adjustments. During installation, ensure the hydraulic valve center height aligns with the overspeed detector and that one side of the tripping device coincides with the main shaft centerline (as shown in Figure 3). Then, tighten the bolts.

4. Before tightening the 8 bolts connecting the two semicircular detector mounting brackets, inspect and ensure sufficient clearance on each side between the flange ring, counterweight device, and detector. This guarantees the detector mounting bracket can be pre-tightened onto the spindle. If no clearance exists, the site must address the issue before reinstallation.

5. Alternately tighten the 8 bolts on both flanges (increasing torque alternately to 60N.M, 90N.M, and finally 120N.M). Before tightening the bolts, ensure the detector is aligned with the tripping device's actuating arm. The final tightening torque for each bolt on the nut must be 120 Newton meters (120N.M).

Note: The above tightening torque must be strictly controlled using tools such as a torque wrench and must not be less than or exceed the specified tightening torque: 120 Newton meters (120 N·M) ±2%.

6. Install the protector on its bracket, check and ensure that the radial clearance between the trip arm of the protector and the detector is 3.0 mm, then tighten the bolts. If the clearance is not 3.0 mm, adjust the fine-tuning screw of the protector (when the clearance is less than 3.0 mm, loosen the forward fine-tuning screw 1 in Figure 4 and tighten the backward fine-tuning screw 9 in Figure 4; when the clearance is greater than 3.0 mm, loosen the backward fine-tuning screw 9 in Figure 4 and tighten the forward fine-tuning screw 1 in Figure 4), ensuring the final installation clearance is exactly 3.0 mm radially (note this step is crucial). The dedicated tools provided with the delivery can be used to verify whether the installation clearance is 3.0 mm.