Electric contact bimetallic thermometers are used in production sites for automatic temperature control and alarm. Directly measure the temperature of body, steam, and gas media within the range of -80 to 500 ℃ in various production processes. On site temperature display, intuitive and convenient; Equipped with automatic power-off and alarm functions; Safe and reliable, with a long service life; Multiple structural forms can meet different requirements.
2、 Main technical parameters
1. Product execution standard: JB/T8803-1998 GB3836-83
2. Scale dial nominal diameter: 100
3. Accuracy level: (1.0), 1.5
4. Thermal response time: ≤ 40S
5. Protection level: IP55
6. Normal working atmospheric conditions: temperature -25~+55 ℃, relative humidity ≤ 85%
7. Setpoint error: The set point error should not exceed 1.5 times the basic error limit.
8. Switching error: The switching error should not exceed 1.5 times the basic error limit.
9. Switching repeatability: The limit range of switching repeatability should not exceed 1/2 of the absolute value of the basic error limit.
10. Electric contact capacity: 10VA, AC220V/0.7A, DC24V/0.7A
3、 Selection

Selection notice: Please provide the model, dial diameter, accuracy level, installation and fixing form, temperature measurement range, protective tube material, length or insertion depth.
Selection example: Universal type, dial diameter of Φ 100, temperature measurement range of 0-400 ℃, 1.5 levels, movable external thread M27 × 2, length 450mm
WSSX-481, 0-400 ℃, L=450, M27 × 2, Class 1.5
4、 Model and specifications

5、 Electrical contact wiring method